CLMNJ - NYE RHEOTEMP 500

  • MSDS: CLMNJ
  • Manufacturer: NYE LUBRICANTS INC
  • Product Name: NYE RHEOTEMP 500
  • National Stock Number: 9150-01-289-0423
Product Identification

Product ID:NYE RHEOTEMP 500
MSDS Date:09/11/1992
FSC:9150
NIIN:01-289-0423
Status Code:A
MSDS Number: CLMNJ

Responsible Party
NYE LUBRICANTS INC
12 HOWLAND RD
NEW BEDFORD, MA 02742-8927
US

Emergency Phone: 508-758-4408;508-993-4685

Info Phone: 508-996-6721

Cage: 98354

Contractor
TORRINGTON INGERSOL RAND
1008 TORRINGTON, CT 06790-1008 US

Telephone: 860-626-2000

Cage: 21335

Ingredients

TRIXYLENYL PHOSPHATE (MIXED XYLYL)

CAS: 25155-23-1

RTECS: ZE8320000


DIPHENYL-P-PHENYLENEDIAMINE

CAS: 74-31-7


ALIPHATIC POLYESTER OIL

CAS: 26745-88-0

OSHA PEL NONE ESTABLISHED

ACGIH TLV: NONE ESTABLISHED


WHITE MINERAL OIL

CAS: 8042-47-5

RTECS: PY8047000

OSHA PEL NONE ESTABLISHED

ACGIH TLV: NONE ESTABLISHED


DIINDOGEN

CAS: 482-89-3

OSHA PEL NONE ESTABLISHED

ACGIH TLV: NONE ESTABLISHED


SODIUM MYRISTATE

CAS: 822-12-8

OSHA PEL NONE ESTABLISHED

ACGIH TLV: NONE ESTABLISHED

Hazards

LD50 LC50 Mixture:NONE GIVEN FOR PRODUCT AS A WHOLE
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: SKIN, EYES, RESPIRATORY
PASSAGES (HIGH TEMPERATURES ONLY). ACUTE: POSSIBLE SKIN AND EYE
IRRITATION. POSSIBLE RESPIRATORY PASSAGE IRRITATION AT HIGH
TEMPERATURES. NAUSEA AND ABDOMINAL PA IN AND IF LARGE QUANTITIES
INGESTED OR ABSORBED THROUGH SKIN. PARALYSIS IF ABSORBED OR
INGESTED IN LARGE QUANTITIES. CHRONIC: NONE KNOWN.
Explanation of Carcinogenicity:THIS PRODUCT IS NOT CONSIDERED A HUMAN
CARCINOGEN BY ANY RECOGNIZED SOURCE.
Effects of Overexposure:NAUSEA, DIARRHEA, AND ABDOMINAL PAIN FOLLOWED
BY SORENESS OF LOWER LEGS AND NUMBNESS OF TOES.
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:EYE: WASH THOROUGHLY; CONTACT PHYSICIAN IF IRRITATION
PERSISTS. SKIN: WASH THOROUGHLY WITH SOAP AND WATER. INHALTION:
MOVE TO FRESH AIR AND REFER TO A PHYSICIAN FOR TREATMENT.
INGESTION: OBTAIN IMMEDI ATE MEDICAL ATTENTION IF INGESTED OR IF
SYMPTOMS DEVELOP. EXERCISE ORDINARY MEASURES OF PERSONAL HYGIENE.
AVOID CONTAMINATION OF CIGARETTES OR OTHER TOBACCO PRODUCTS.

Fire Fighting

Flash Point Method:COC
Flash Point:=232.2C, 450.F
Extinguishing Media:SMALL FIRE: USE CO2 OR DRY CHEMICAL. LARGE FIRE:
USE FOAM OR WATER SPRAY.
Fire Fighting Procedures:AVOID SMOKE INHALATION. WATER OR FOAM MAY
CAUSE FROTHING. IF CLOSED DRUMS ARE EXPOSED TO FIRE, KEEP COOL WITH
WATER SPRAY TO PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:REMOVE FREE LIQUID. ADD ABSORBENT (SAND,
EARTH, SAWDUST) TO SPILL AREA. AFTER REMOVING ABSORBENT, WASH
WALKING SURFACES THOROUGHLY WITH DETERGENT AND WATER TO REDUCE
SLIPPING HAZARD.
Neutralizing Agent:NO DATA PROVIDED BY MANUFACTURER

Handling

Handling and Storage Precautions:STORAGE SEGREGATION: NOT NEEDED. AVOID
EXTENDED SKIN EXPOSURE. EXERCISE ORDINARY CARE IN HANDLING
CHEMICALS.
Other Precautions:AVOID CONTAMINATION OF FOOD, CIGARETTES OR OTHER
TOBACCO PRODUCTS. WASH HANDS THOROUGHLY BEFORE SMOKING. USERS
SHOULD BE ALERT TO THE POSSIBILITY THAT VERY SMALL PERCENTAGES OF
THE POPULATION MAY DISP LAY UNEXPECTED ALLERGIC SKIN REACTIONS TO
OTHERWISE INNOCUOUS INDUSTRIAL CHEMICALS AND RAW MATERIALS .

Exposure Controls

Respiratory Protection:NOT REQUIRED UNLESS MISTS, SMOKE OR VAPORS ARE
PRODUCED AT HIGH TEMPERATURES.
Ventilation:NOT REQUIRED UNLESS MISTS, SMOKE OR VAPORS ARE PRODUCED AT
HIGH TEMPERATURES.
Protective Gloves:REQUIRED, ESPECIALLY TO AVOID PROLONGED/REPEATED SKIN
CONTACT.
Eye Protection:SAFETY GLASSES ESPECIALLY IF SPLASH IS LIKELY
Work Hygienic Practices:AVOID CONTAMINATION OF FOOD, CIGARETTES OR
OTHER TOBACCO PRODUCTS. WASH HANDS THOROUGHLY BEFORE SMOKING. WAS
CONTAMINATED CLOTHES BEFORE RE-USE.
Supplemental Safety and Health
TORRINGTON CO LUBE CODE 067.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:NOT VOLITILE
Melt/Freeze Pt:=201.7C, 395.F
Vapor Pres:NOT VOLITILE
Vapor Density:>AIR
Spec Gravity:0.96
Evaporation Rate & Reference:Solubility in Water:INSOLUBLE
Appearance and Odor:SMOOTH, DEEP-BLUE LUBRICATING GREASE WITH MILD ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING MATERIALS
Stability Condition to Avoid:PYROLYSIS
Hazardous Decomposition Products:TOXIC OXIDES OF PHOSPHORUS AS WELL AS
CARBON MONOXIDE AND SMALL AMOUNTS OF OTHER TOXIC FUMES
Conditions to Avoid Polymerization:HAZARDOUS POLYMERIZATION WILL NOT
OCCUR.

Disposal

Waste Disposal Methods:MANY STATES CLASSIFY WASTE LUBRICANTS AS
"HAZARDOUS", WHICH MEANS DISPOSAL ONLY BY LICENSED FIRM. CONSULT
LOCAL, STATE AND FEDERAL REFULATIONS APPLICABLE TO YOUR AREA.

Toxicology

Toxicological Information:TRIXYLENYL PHOSPHATE: LD50 (ORAL, RAT) > 4640
MG/KG; DIPHENYL-P-PHENYLENEDIAMINE LD50 (ORAL, RAT) > 5000 MG/KG.
PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE SKIN IRRITATION.
CONTAINS SMALL AMOUNT OF T RIXYLENYL PHOSPHATE. DO NOT ALLOW ON
FOOD MACHINERY OR ON SURFACES THAT MAY CONTACT FOOD. CAN BE
ABSORBED THROUGH SKIN IF EXPOSED TO HIGH CONCENTRATIONS FOR A LONG
PERIOD. INITIAL SYMPTOMS ARE NAUSEA, DIARRHEA, ABDOMINAL PAIN
FOLLOWED BY SORENESS OF LOWER LEGS AND NUMBNESS OF TOES. INGESTION
OR ABSORPTION OF LARGE AMOUNTS OF THIS COMPONENT CAN CAUSE
APRALYSIS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:NO DATA PROVIDED BY MANUFACTURER

Transport

Transport Information:DOT CLASS: NOT RESTRICTED.

Regulatory

SARA Title III Information:NO DATA PROVIDED BY MANUFACTURER
Federal Regulatory Information:NO DATA PROVIDED BY MANUFACTURER
State Regulatory Information:NO DATA PROVIDED BY MANUFACTURER